• Newest
  • Most reviews

Particular Use Sensors

ModelDescriptionBrandLeadingConditionPriceAction
Particular Use Sensors
BE-A401P
Product Number BE-A201 Part Number BE-A201 Detectable air gap 0.8 mm 0.032 in or more (Note) Sensing air gap refers to the width of an air bubble formed in the entire area of the inner diameter of the tube. Please note that this product cannot sense very small air bubbles or water drops. Sensing object Liquid (Note) Sensing is affected by dirt or residues adhered to the inner wall of the tube. Please maintain the tube regularly. Applicable tube dia. (OD×ID) ø2 mm × ø1 mm ø0.078 in × ø0.039 in (Note) When using a tube out of specifications or it doesn't have a smooth surface, please test sensing on the actual machine before use. Applicable tube type Transparent resin tube (equivalent to PFA) (Note) When using a tube out of specifications or it doesn't have a smooth surface, please test sensing on the actual machine before use. Supply voltage 5 to 24 V DC ±10 % Ripple P-P 10 % or less Current consumption 15 mA or less Output (Incorporated with 2 outputs) NPN open-collector transistor •Maximum sink current: 50 mA •Applied voltage: 30 V DC or less (between output and 0 V) •Residual voltage: 2 V or less (sink current at 50 mA) 1 V or less (sink current at 16 mA) Output (Incorporated with 2 outputs):Output operation Switchable either Liquid-absent-ON or Liquid-present-ON
In StockNew Sealed Under Guarantee
HD-T1C
Sensing width 30 mm 1.181 in (Linearity is specified at 28 mm 1.102 in width.) Sensing range 30 mm 1.181 in (fixed) (Note 2) Pollution degree 3 (Industrial environment) Ambient temperature 0 to +40 ℃ +32 to +104℉ (No dew condensation), Storage: -20 to +55 ℃ -4 to +131℉ Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH Ambient illuminance Incandescent light: 3,000 lx at the light-receiving face, Fluorescent light: 3,000 lx at the light-receiving face Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each Shock resistance 490 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each Emitting element Red LED (Peak emission wavelength: 650 nm 0.026 mil) Receiving element Photodiode
In StockNew Sealed Under Guarantee
SQ4-A22-N
Sensing object Water (Standard liquid) (Note 1) Highly viscous liquid may not be stably detected. (Note 2) The agents mentioned above are examples. It may not be detected depending on viscosity the agent. Before using this device, check the detecting liquid and installation condition. Power voltage 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less Current consumption 30 mA or less Utilization category DC-12, DC-13 Detection output(Leakage detection) PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: Same as the supply voltage (between detection output and +V) - Residual voltage: 2.5 V or less (at 50 mA source current) Detection output(Leakage detection):Response time 10 ms or less Detection output(Leakage detection):Output operation ON when normal condition or initial detection, OFF when detection leakage or wrong installation
In StockNew Sealed Under Guarantee
EX-F62-PN-C5
Sensing object Agent, such as Water, Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. Note : Highly viscous liquid may not be detected stably. Note : The agents mentioned above are examples. For details, please contact our office. Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office. Supply voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less Current consumption 15 mA or less Output NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 23 mA sink current) Output:Output operation In normal state: ON, When leak detected or the sensor is mounted improperly: OFF
In StockNew Sealed Under Guarantee
EX-F1-C5
Sensing object Agent, such as Water, Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. Note : Highly viscous liquid may not be detected stably. Note : The agents mentioned above are examples. For details, please contact our office. Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office. Supply voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less Current consumption 15 mA or less Output NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 25 mA sink current) Output:Output operation In normal state: ON, When leak detected or the sensor is mounted improperly: OFF
In StockNew Sealed Under Guarantee
EZ-11-PN
Sensing range 5 m 16.404 ft (without container or pipe) (Note):The sensing range shortens depending on the thickness, material, color, etc., of the container or pipe. Sensing object ø12 mm ø0.472 mm or more liquid which contains water, or opaque object (Note):If there are two slit masks on both sides, the size of those slit masks represents the min. sensing object. Supply voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less Current consumption Emitter: 25 mA or less, Receiver: 25 mA or less Output NPN open-collector transistor ・Maximum sink current: 100 mA ・Applied voltage: 30 V DC or less (between output and 0 V) ・Residual voltage: 1.5 V or less (at 100 mA sink current) 0.4 V or less (at 16 mA sink current) Output:Utilization category DC-12 or DC-13 Output:Output operation Switchable either Light-ON or Dark-ON Output:Short-circuit protection Switchable either Light-ON or Dark-ON Response time 12 ms or less
In StockNew Sealed Under Guarantee
FD-L54
In StockNew Sealed Under Guarantee
LX-101-P-Z
In StockNew Sealed Under Guarantee
BE-A201
Product Number BE-A201 Part Number BE-A201 Detectable air gap 0.8 mm 0.032 in or more (Note) Sensing air gap refers to the width of an air bubble formed in the entire area of the inner diameter of the tube. Please note that this product cannot sense very small air bubbles or water drops. Sensing object Liquid (Note) Sensing is affected by dirt or residues adhered to the inner wall of the tube. Please maintain the tube regularly. Applicable tube dia. (OD×ID) ø2 mm × ø1 mm ø0.078 in × ø0.039 in (Note) When using a tube out of specifications or it doesn't have a smooth surface, please test sensing on the actual machine before use. Applicable tube type Transparent resin tube (equivalent to PFA) (Note) When using a tube out of specifications or it doesn't have a smooth surface, please test sensing on the actual machine before use. Supply voltage 5 to 24 V DC ±10 % Ripple P-P 10 % or less Current consumption 15 mA or less Output (Incorporated with 2 outputs) NPN open-collector transistor •Maximum sink current: 50 mA •Applied voltage: 30 V DC or less (between output and 0 V) •Residual voltage: 2 V or less (sink current at 50 mA) 1 V or less (sink current at 16 mA) Output (Incorporated with 2 outputs):Output operation Switchable either Liquid-absent-ON or Liquid-present-ON
In StockNew Sealed Under Guarantee
BE-A201P
Product Number BE-A201 Part Number BE-A201 Detectable air gap 0.8 mm 0.032 in or more (Note) Sensing air gap refers to the width of an air bubble formed in the entire area of the inner diameter of the tube. Please note that this product cannot sense very small air bubbles or water drops. Sensing object Liquid (Note) Sensing is affected by dirt or residues adhered to the inner wall of the tube. Please maintain the tube regularly. Applicable tube dia. (OD×ID) ø2 mm × ø1 mm ø0.078 in × ø0.039 in (Note) When using a tube out of specifications or it doesn't have a smooth surface, please test sensing on the actual machine before use. Applicable tube type Transparent resin tube (equivalent to PFA) (Note) When using a tube out of specifications or it doesn't have a smooth surface, please test sensing on the actual machine before use. Supply voltage 5 to 24 V DC ±10 % Ripple P-P 10 % or less Current consumption 15 mA or less Output (Incorporated with 2 outputs) NPN open-collector transistor •Maximum sink current: 50 mA •Applied voltage: 30 V DC or less (between output and 0 V) •Residual voltage: 2 V or less (sink current at 50 mA) 1 V or less (sink current at 16 mA) Output (Incorporated with 2 outputs):Output operation Switchable either Liquid-absent-ON or Liquid-present-ON
In StockNew Sealed Under Guarantee
BE-A301
Product Number BE-A201 Part Number BE-A201 Detectable air gap 0.8 mm 0.032 in or more (Note) Sensing air gap refers to the width of an air bubble formed in the entire area of the inner diameter of the tube. Please note that this product cannot sense very small air bubbles or water drops. Sensing object Liquid (Note) Sensing is affected by dirt or residues adhered to the inner wall of the tube. Please maintain the tube regularly. Applicable tube dia. (OD×ID) ø2 mm × ø1 mm ø0.078 in × ø0.039 in (Note) When using a tube out of specifications or it doesn't have a smooth surface, please test sensing on the actual machine before use. Applicable tube type Transparent resin tube (equivalent to PFA) (Note) When using a tube out of specifications or it doesn't have a smooth surface, please test sensing on the actual machine before use. Supply voltage 5 to 24 V DC ±10 % Ripple P-P 10 % or less Current consumption 15 mA or less Output (Incorporated with 2 outputs) NPN open-collector transistor •Maximum sink current: 50 mA •Applied voltage: 30 V DC or less (between output and 0 V) •Residual voltage: 2 V or less (sink current at 50 mA) 1 V or less (sink current at 16 mA) Output (Incorporated with 2 outputs):Output operation Switchable either Liquid-absent-ON or Liquid-present-ON
In StockNew Sealed Under Guarantee
BE-A301P
Product Number BE-A201 Part Number BE-A201 Detectable air gap 0.8 mm 0.032 in or more (Note) Sensing air gap refers to the width of an air bubble formed in the entire area of the inner diameter of the tube. Please note that this product cannot sense very small air bubbles or water drops. Sensing object Liquid (Note) Sensing is affected by dirt or residues adhered to the inner wall of the tube. Please maintain the tube regularly. Applicable tube dia. (OD×ID) ø2 mm × ø1 mm ø0.078 in × ø0.039 in (Note) When using a tube out of specifications or it doesn't have a smooth surface, please test sensing on the actual machine before use. Applicable tube type Transparent resin tube (equivalent to PFA) (Note) When using a tube out of specifications or it doesn't have a smooth surface, please test sensing on the actual machine before use. Supply voltage 5 to 24 V DC ±10 % Ripple P-P 10 % or less Current consumption 15 mA or less Output (Incorporated with 2 outputs) NPN open-collector transistor •Maximum sink current: 50 mA •Applied voltage: 30 V DC or less (between output and 0 V) •Residual voltage: 2 V or less (sink current at 50 mA) 1 V or less (sink current at 16 mA) Output (Incorporated with 2 outputs):Output operation Switchable either Liquid-absent-ON or Liquid-present-ON
In StockNew Sealed Under Guarantee
BE-A401
Product Number BE-A201 Part Number BE-A201 Detectable air gap 0.8 mm 0.032 in or more (Note) Sensing air gap refers to the width of an air bubble formed in the entire area of the inner diameter of the tube. Please note that this product cannot sense very small air bubbles or water drops. Sensing object Liquid (Note) Sensing is affected by dirt or residues adhered to the inner wall of the tube. Please maintain the tube regularly. Applicable tube dia. (OD×ID) ø2 mm × ø1 mm ø0.078 in × ø0.039 in (Note) When using a tube out of specifications or it doesn't have a smooth surface, please test sensing on the actual machine before use. Applicable tube type Transparent resin tube (equivalent to PFA) (Note) When using a tube out of specifications or it doesn't have a smooth surface, please test sensing on the actual machine before use. Supply voltage 5 to 24 V DC ±10 % Ripple P-P 10 % or less Current consumption 15 mA or less Output (Incorporated with 2 outputs) NPN open-collector transistor •Maximum sink current: 50 mA •Applied voltage: 30 V DC or less (between output and 0 V) •Residual voltage: 2 V or less (sink current at 50 mA) 1 V or less (sink current at 16 mA) Output (Incorporated with 2 outputs):Output operation Switchable either Liquid-absent-ON or Liquid-present-ON
In StockNew Sealed Under Guarantee
HD-T1030
Sensing width 30 mm 1.181 in (Linearity is specified at 28 mm 1.102 in width.) Sensing range 30 mm 1.181 in (fixed) (Note 2) Pollution degree 3 (Industrial environment) Ambient temperature 0 to +40 ℃ +32 to +104℉ (No dew condensation), Storage: -20 to +55 ℃ -4 to +131℉ Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH Ambient illuminance Incandescent light: 3,000 lx at the light-receiving face, Fluorescent light: 3,000 lx at the light-receiving face Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each Shock resistance 490 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each Emitting element Red LED (Peak emission wavelength: 650 nm 0.026 mil) Receiving element Photodiode
In StockNew Sealed Under Guarantee
SQ4-A21-P
Sensing object Water (Standard liquid) (Note 1) Highly viscous liquid may not be stably detected. (Note 2) The agents mentioned above are examples. It may not be detected depending on viscosity the agent. Before using this device, check the detecting liquid and installation condition. Power voltage 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less Current consumption 30 mA or less Utilization category DC-12, DC-13 Detection output(Leakage detection) PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: Same as the supply voltage (between detection output and +V) - Residual voltage: 2.5 V or less (at 50 mA source current) Detection output(Leakage detection):Response time 10 ms or less Detection output(Leakage detection):Output operation ON when normal condition or initial detection, OFF when detection leakage or wrong installation
In StockNew Sealed Under Guarantee
SQ4-A21-N
Sensing object Water (Standard liquid) (Note 1) Highly viscous liquid may not be stably detected. (Note 2) The agents mentioned above are examples. It may not be detected depending on viscosity the agent. Before using this device, check the detecting liquid and installation condition. Power voltage 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less Current consumption 30 mA or less Utilization category DC-12, DC-13 Detection output(Leakage detection) PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: Same as the supply voltage (between detection output and +V) - Residual voltage: 2.5 V or less (at 50 mA source current) Detection output(Leakage detection):Response time 10 ms or less Detection output(Leakage detection):Output operation ON when normal condition or initial detection, OFF when detection leakage or wrong installation
In StockNew Sealed Under Guarantee
SQ4-A22-P
Sensing object Water (Standard liquid) (Note 1) Highly viscous liquid may not be stably detected. (Note 2) The agents mentioned above are examples. It may not be detected depending on viscosity the agent. Before using this device, check the detecting liquid and installation condition. Power voltage 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less Current consumption 30 mA or less Utilization category DC-12, DC-13 Detection output(Leakage detection) PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: Same as the supply voltage (between detection output and +V) - Residual voltage: 2.5 V or less (at 50 mA source current) Detection output(Leakage detection):Response time 10 ms or less Detection output(Leakage detection):Output operation ON when normal condition or initial detection, OFF when detection leakage or wrong installation
In StockNew Sealed Under Guarantee
EX-F61
Sensing object Agent, such as Water, Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. Note : Highly viscous liquid may not be detected stably. Note : The agents mentioned above are examples. For details, please contact our office. Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office. Supply voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less Current consumption 15 mA or less Output NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 16 mA sink current) Output:Output operation In normal state: ON, When leak detected or the sensor is mounted improperly: OFF
In StockNew Sealed Under Guarantee
EX-F61-PN
Sensing object Agent, such as Water, Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. Note : Highly viscous liquid may not be detected stably. Note : The agents mentioned above are examples. For details, please contact our office. Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office. Supply voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less Current consumption 15 mA or less Output NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 17 mA sink current) Output:Output operation In normal state: ON, When leak detected or the sensor is mounted improperly: OFF
In StockNew Sealed Under Guarantee
EX-F62
Sensing object Agent, such as Water, Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. Note : Highly viscous liquid may not be detected stably. Note : The agents mentioned above are examples. For details, please contact our office. Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office. Supply voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less Current consumption 15 mA or less Output NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 18 mA sink current) Output:Output operation In normal state: ON, When leak detected or the sensor is mounted improperly: OFF
In StockNew Sealed Under Guarantee