• Home
  • Frequency Converter
  • powtran

  • KEMATION

  • YASKAWA

  • Newest
  • Most reviews
ModelDescriptionBrandLeadingConditionPriceAction
MK300
AMK3000154
Standard applicable motor output (kW) 0.75kW Rated output: rated voltage three-phase 380V~460V AC (power supply voltage ratio) Rated output: Overload current Rated standard load specification: 150% of rated output current for 1 minute Light load specification: 120% of rated output current for 1 minute Input power supply: Phase number, voltage, frequency three-phase 380V~460V AC 50Hz/60Hz Input power supply: The voltage can vary by+10%, -15% of the rated input AC voltage Input power supply: The frequency allows for a variation of ± 5% of the rated input frequency Input power supply: Instantaneous voltage drop tolerance · Continue running above 323V AC · Continue running for 15ms when dropped below 323V AC Output frequency: Frequency range V/F Control: 0.2Hz~400Hz Sensorless vector control: 0.5Hz~120Hz Output frequency: Frequency display digital display
In StockNew Sealed Under Guarantee
AMK3000P22
Quasi applicable motor output (kW) 0.2kW Rated output: rated voltage three-phase 200V~230V AC (power supply voltage ratio) Rated output: Overload current Rated standard load specification: 150% of rated output current for 1 minute Light load specification: 120% of rated output current for 1 minute Input power supply: Phase number, voltage, frequency, single-phase 200V~230V AC 50Hz/60Hz Input power supply: The voltage can vary by+10%, -15% of the rated input AC voltage Input power supply: The frequency allows for a variation of ± 5% of the rated input frequency Input power supply: Instantaneous voltage drop tolerance · Continue running above 165V AC · Continue running for 15ms when dropped below 165V AC Output frequency: Frequency range V/F Control: 0.2Hz~400Hz Sensorless vector control: 0.5Hz~120Hz Output frequency: Frequency display digital display Output frequency: Frequency accuracy Analog setting: Within ± 0.5% of the highest set frequency (25 ℃± 10 ℃) Digital setting: Within ± 0.01% of the highest set frequency (-10 ℃~+50 ℃) Output frequency: Frequency resolution: 0.1Hz (in 50Hz/60Hz mode) for analog setting: 0.1Hz for digital setting Frequency converter control method: High carrier frequency sine wave PWM control (optional for V/F control or sensorless vector control)
In StockNew Sealed Under Guarantee
AMK3000P42
Quasi applicable motor output (kW) 0.2kW Rated output: rated voltage three-phase 200V~230V AC (power supply voltage ratio) Rated output: Overload current Rated standard load specification: 150% of rated output current for 1 minute Light load specification: 120% of rated output current for 1 minute Input power supply: Phase number, voltage, frequency, single-phase 200V~230V AC 50Hz/60Hz Input power supply: The voltage can vary by+10%, -15% of the rated input AC voltage Input power supply: The frequency allows for a variation of ± 5% of the rated input frequency Input power supply: Instantaneous voltage drop tolerance · Continue running above 165V AC · Continue running for 15ms when dropped below 165V AC Output frequency: Frequency range V/F Control: 0.2Hz~400Hz Sensorless vector control: 0.5Hz~120Hz Output frequency: Frequency display digital display Output frequency: Frequency accuracy Analog setting: Within ± 0.5% of the highest set frequency (25 ℃± 10 ℃) Digital setting: Within ± 0.01% of the highest set frequency (-10 ℃~+50 ℃) Output frequency: Frequency resolution: 0.1Hz (in 50Hz/60Hz mode) for analog setting: 0.1Hz for digital setting Frequency converter control method: High carrier frequency sine wave PWM control (optional for V/F control or sensorless vector control)
In StockNew Sealed Under Guarantee
AMK3000P72
Quasi applicable motor output (kW) 0.2kW Rated output: rated voltage three-phase 200V~230V AC (power supply voltage ratio) Rated output: Overload current Rated standard load specification: 150% of rated output current for 1 minute Light load specification: 120% of rated output current for 1 minute Input power supply: Phase number, voltage, frequency, single-phase 200V~230V AC 50Hz/60Hz Input power supply: The voltage can vary by+10%, -15% of the rated input AC voltage Input power supply: The frequency allows for a variation of ± 5% of the rated input frequency Input power supply: Instantaneous voltage drop tolerance · Continue running above 165V AC · Continue running for 15ms when dropped below 165V AC Output frequency: Frequency range V/F Control: 0.2Hz~400Hz Sensorless vector control: 0.5Hz~120Hz Output frequency: Frequency display digital display Output frequency: Frequency accuracy Analog setting: Within ± 0.5% of the highest set frequency (25 ℃± 10 ℃) Digital setting: Within ± 0.01% of the highest set frequency (-10 ℃~+50 ℃) Output frequency: Frequency resolution: 0.1Hz (in 50Hz/60Hz mode) for analog setting: 0.1Hz for digital setting Frequency converter control method: High carrier frequency sine wave PWM control (optional for V/F control or sensorless vector control)
In StockNew Sealed Under Guarantee
AMK3001P52
Quasi applicable motor output (kW) 0.2kW Rated output: rated voltage three-phase 200V~230V AC (power supply voltage ratio) Rated output: Overload current Rated standard load specification: 150% of rated output current for 1 minute Light load specification: 120% of rated output current for 1 minute Input power supply: Phase number, voltage, frequency, single-phase 200V~230V AC 50Hz/60Hz Input power supply: The voltage can vary by+10%, -15% of the rated input AC voltage Input power supply: The frequency allows for a variation of ± 5% of the rated input frequency Input power supply: Instantaneous voltage drop tolerance · Continue running above 165V AC · Continue running for 15ms when dropped below 165V AC Output frequency: Frequency range V/F Control: 0.2Hz~400Hz Sensorless vector control: 0.5Hz~120Hz Output frequency: Frequency display digital display Output frequency: Frequency accuracy Analog setting: Within ± 0.5% of the highest set frequency (25 ℃± 10 ℃) Digital setting: Within ± 0.01% of the highest set frequency (-10 ℃~+50 ℃) Output frequency: Frequency resolution: 0.1Hz (in 50Hz/60Hz mode) for analog setting: 0.1Hz for digital setting Frequency converter control method: High carrier frequency sine wave PWM control (optional for V/F control or sensorless vector control)
In StockNew Sealed Under Guarantee
AMK3002P22
Quasi applicable motor output (kW) 0.2kW Rated output: rated voltage three-phase 200V~230V AC (power supply voltage ratio) Rated output: Overload current Rated standard load specification: 150% of rated output current for 1 minute Light load specification: 120% of rated output current for 1 minute Input power supply: Phase number, voltage, frequency, single-phase 200V~230V AC 50Hz/60Hz Input power supply: The voltage can vary by+10%, -15% of the rated input AC voltage Input power supply: The frequency allows for a variation of ± 5% of the rated input frequency Input power supply: Instantaneous voltage drop tolerance · Continue running above 165V AC · Continue running for 15ms when dropped below 165V AC Output frequency: Frequency range V/F Control: 0.2Hz~400Hz Sensorless vector control: 0.5Hz~120Hz Output frequency: Frequency display digital display Output frequency: Frequency accuracy Analog setting: Within ± 0.5% of the highest set frequency (25 ℃± 10 ℃) Digital setting: Within ± 0.01% of the highest set frequency (-10 ℃~+50 ℃) Output frequency: Frequency resolution: 0.1Hz (in 50Hz/60Hz mode) for analog setting: 0.1Hz for digital setting Frequency converter control method: High carrier frequency sine wave PWM control (optional for V/F control or sensorless vector control)
In StockNew Sealed Under Guarantee
AMK3000P74
Standard applicable motor output (kW) 0.75kW Rated output: rated voltage three-phase 380V~460V AC (power supply voltage ratio) Rated output: Overload current Rated standard load specification: 150% of rated output current for 1 minute Light load specification: 120% of rated output current for 1 minute Input power supply: Phase number, voltage, frequency three-phase 380V~460V AC 50Hz/60Hz Input power supply: The voltage can vary by+10%, -15% of the rated input AC voltage Input power supply: The frequency allows for a variation of ± 5% of the rated input frequency Input power supply: Instantaneous voltage drop tolerance · Continue running above 323V AC · Continue running for 15ms when dropped below 323V AC Output frequency: Frequency range V/F Control: 0.2Hz~400Hz Sensorless vector control: 0.5Hz~120Hz Output frequency: Frequency display digital display
In StockNew Sealed Under Guarantee
AMK3001P54
Standard applicable motor output (kW) 0.75kW Rated output: rated voltage three-phase 380V~460V AC (power supply voltage ratio) Rated output: Overload current Rated standard load specification: 150% of rated output current for 1 minute Light load specification: 120% of rated output current for 1 minute Input power supply: Phase number, voltage, frequency three-phase 380V~460V AC 50Hz/60Hz Input power supply: The voltage can vary by+10%, -15% of the rated input AC voltage Input power supply: The frequency allows for a variation of ± 5% of the rated input frequency Input power supply: Instantaneous voltage drop tolerance · Continue running above 323V AC · Continue running for 15ms when dropped below 323V AC Output frequency: Frequency range V/F Control: 0.2Hz~400Hz Sensorless vector control: 0.5Hz~120Hz Output frequency: Frequency display digital display
In StockNew Sealed Under Guarantee
AMK3002P24
Standard applicable motor output (kW) 0.75kW Rated output: rated voltage three-phase 380V~460V AC (power supply voltage ratio) Rated output: Overload current Rated standard load specification: 150% of rated output current for 1 minute Light load specification: 120% of rated output current for 1 minute Input power supply: Phase number, voltage, frequency three-phase 380V~460V AC 50Hz/60Hz Input power supply: The voltage can vary by+10%, -15% of the rated input AC voltage Input power supply: The frequency allows for a variation of ± 5% of the rated input frequency Input power supply: Instantaneous voltage drop tolerance · Continue running above 323V AC · Continue running for 15ms when dropped below 323V AC Output frequency: Frequency range V/F Control: 0.2Hz~400Hz Sensorless vector control: 0.5Hz~120Hz Output frequency: Frequency display digital display
In StockNew Sealed Under Guarantee
AMK3003P74
Standard applicable motor output (kW) 0.75kW Rated output: rated voltage three-phase 380V~460V AC (power supply voltage ratio) Rated output: Overload current Rated standard load specification: 150% of rated output current for 1 minute Light load specification: 120% of rated output current for 1 minute Input power supply: Phase number, voltage, frequency three-phase 380V~460V AC 50Hz/60Hz Input power supply: The voltage can vary by+10%, -15% of the rated input AC voltage Input power supply: The frequency allows for a variation of ± 5% of the rated input frequency Input power supply: Instantaneous voltage drop tolerance · Continue running above 323V AC · Continue running for 15ms when dropped below 323V AC Output frequency: Frequency range V/F Control: 0.2Hz~400Hz Sensorless vector control: 0.5Hz~120Hz Output frequency: Frequency display digital display
In StockNew Sealed Under Guarantee
AMK3005P54
Standard applicable motor output (kW) 0.75kW Rated output: rated voltage three-phase 380V~460V AC (power supply voltage ratio) Rated output: Overload current Rated standard load specification: 150% of rated output current for 1 minute Light load specification: 120% of rated output current for 1 minute Input power supply: Phase number, voltage, frequency three-phase 380V~460V AC 50Hz/60Hz Input power supply: The voltage can vary by+10%, -15% of the rated input AC voltage Input power supply: The frequency allows for a variation of ± 5% of the rated input frequency Input power supply: Instantaneous voltage drop tolerance · Continue running above 323V AC · Continue running for 15ms when dropped below 323V AC Output frequency: Frequency range V/F Control: 0.2Hz~400Hz Sensorless vector control: 0.5Hz~120Hz Output frequency: Frequency display digital display
In StockNew Sealed Under Guarantee
AMK3007P54
Standard applicable motor output (kW) 0.75kW Rated output: rated voltage three-phase 380V~460V AC (power supply voltage ratio) Rated output: Overload current Rated standard load specification: 150% of rated output current for 1 minute Light load specification: 120% of rated output current for 1 minute Input power supply: Phase number, voltage, frequency three-phase 380V~460V AC 50Hz/60Hz Input power supply: The voltage can vary by+10%, -15% of the rated input AC voltage Input power supply: The frequency allows for a variation of ± 5% of the rated input frequency Input power supply: Instantaneous voltage drop tolerance · Continue running above 323V AC · Continue running for 15ms when dropped below 323V AC Output frequency: Frequency range V/F Control: 0.2Hz~400Hz Sensorless vector control: 0.5Hz~120Hz Output frequency: Frequency display digital display
In StockNew Sealed Under Guarantee
AMK3000114
Standard applicable motor output (kW) 0.75kW Rated output: rated voltage three-phase 380V~460V AC (power supply voltage ratio) Rated output: Overload current Rated standard load specification: 150% of rated output current for 1 minute Light load specification: 120% of rated output current for 1 minute Input power supply: Phase number, voltage, frequency three-phase 380V~460V AC 50Hz/60Hz Input power supply: The voltage can vary by+10%, -15% of the rated input AC voltage Input power supply: The frequency allows for a variation of ± 5% of the rated input frequency Input power supply: Instantaneous voltage drop tolerance · Continue running above 323V AC · Continue running for 15ms when dropped below 323V AC Output frequency: Frequency range V/F Control: 0.2Hz~400Hz Sensorless vector control: 0.5Hz~120Hz Output frequency: Frequency display digital display
In StockNew Sealed Under Guarantee
MK500
AMK5000154
Standard applicable motor output (kW) 0.75kW Rated output: rated voltage three-phase 380V~460V AC (power supply voltage ratio) Rated output: Overload current Rated standard load specification: 150% of rated output current for 1 minute Light load specification: 120% of rated output current for 1 minute Input power supply: Phase number, voltage, frequency three-phase 380V~460V AC 50Hz/60Hz Input power supply: The voltage can vary by+10%, -15% of the rated input AC voltage Input power supply: The frequency allows for a variation of ± 5% of the rated input frequency Input power supply: Instantaneous voltage drop tolerance · Continue running above 323V AC · Continue running for 15ms when dropped below 323V AC Output frequency: Frequency range V/F Control: 0.2Hz~400Hz Sensorless vector control: 0.5Hz~120Hz Output frequency: Frequency display digital display
In StockNew Sealed Under Guarantee
AMK5000P42
Standard applicable motor output (kW) 0.75kW Rated output: rated voltage three-phase 380V~460V AC (power supply voltage ratio) Rated output: Overload current Rated standard load specification: 150% of rated output current for 1 minute Light load specification: 120% of rated output current for 1 minute Input power supply: Phase number, voltage, frequency three-phase 380V~460V AC 50Hz/60Hz Input power supply: The voltage can vary by+10%, -15% of the rated input AC voltage Input power supply: The frequency allows for a variation of ± 5% of the rated input frequency Input power supply: Instantaneous voltage drop tolerance · Continue running above 323V AC · Continue running for 15ms when dropped below 323V AC Output frequency: Frequency range V/F Control: 0.2Hz~400Hz Sensorless vector control: 0.5Hz~120Hz Output frequency: Frequency display digital display
In StockNew Sealed Under Guarantee
AMK5000P72
Standard applicable motor output (kW) 0.75kW Rated output: rated voltage three-phase 380V~460V AC (power supply voltage ratio) Rated output: Overload current Rated standard load specification: 150% of rated output current for 1 minute Light load specification: 120% of rated output current for 1 minute Input power supply: Phase number, voltage, frequency three-phase 380V~460V AC 50Hz/60Hz Input power supply: The voltage can vary by+10%, -15% of the rated input AC voltage Input power supply: The frequency allows for a variation of ± 5% of the rated input frequency Input power supply: Instantaneous voltage drop tolerance · Continue running above 323V AC · Continue running for 15ms when dropped below 323V AC Output frequency: Frequency range V/F Control: 0.2Hz~400Hz Sensorless vector control: 0.5Hz~120Hz Output frequency: Frequency display digital display
In StockNew Sealed Under Guarantee
AMK5001P52
Standard applicable motor output (kW) 0.75kW Rated output: rated voltage three-phase 380V~460V AC (power supply voltage ratio) Rated output: Overload current Rated standard load specification: 150% of rated output current for 1 minute Light load specification: 120% of rated output current for 1 minute Input power supply: Phase number, voltage, frequency three-phase 380V~460V AC 50Hz/60Hz Input power supply: The voltage can vary by+10%, -15% of the rated input AC voltage Input power supply: The frequency allows for a variation of ± 5% of the rated input frequency Input power supply: Instantaneous voltage drop tolerance · Continue running above 323V AC · Continue running for 15ms when dropped below 323V AC Output frequency: Frequency range V/F Control: 0.2Hz~400Hz Sensorless vector control: 0.5Hz~120Hz Output frequency: Frequency display digital display
In StockNew Sealed Under Guarantee
AMK5002P22
Standard applicable motor output (kW) 0.75kW Rated output: rated voltage three-phase 380V~460V AC (power supply voltage ratio) Rated output: Overload current Rated standard load specification: 150% of rated output current for 1 minute Light load specification: 120% of rated output current for 1 minute Input power supply: Phase number, voltage, frequency three-phase 380V~460V AC 50Hz/60Hz Input power supply: The voltage can vary by+10%, -15% of the rated input AC voltage Input power supply: The frequency allows for a variation of ± 5% of the rated input frequency Input power supply: Instantaneous voltage drop tolerance · Continue running above 323V AC · Continue running for 15ms when dropped below 323V AC Output frequency: Frequency range V/F Control: 0.2Hz~400Hz Sensorless vector control: 0.5Hz~120Hz Output frequency: Frequency display digital display
In StockNew Sealed Under Guarantee
AMK5000P74
Standard applicable motor output (kW) 0.75kW Rated output: rated voltage three-phase 380V~460V AC (power supply voltage ratio) Rated output: Overload current Rated standard load specification: 150% of rated output current for 1 minute Light load specification: 120% of rated output current for 1 minute Input power supply: Phase number, voltage, frequency three-phase 380V~460V AC 50Hz/60Hz Input power supply: The voltage can vary by+10%, -15% of the rated input AC voltage Input power supply: The frequency allows for a variation of ± 5% of the rated input frequency Input power supply: Instantaneous voltage drop tolerance · Continue running above 323V AC · Continue running for 15ms when dropped below 323V AC Output frequency: Frequency range V/F Control: 0.2Hz~400Hz Sensorless vector control: 0.5Hz~120Hz Output frequency: Frequency display digital display
In StockNew Sealed Under Guarantee
AMK5001P54
Standard applicable motor output (kW) 0.75kW Rated output: rated voltage three-phase 380V~460V AC (power supply voltage ratio) Rated output: Overload current Rated standard load specification: 150% of rated output current for 1 minute Light load specification: 120% of rated output current for 1 minute Input power supply: Phase number, voltage, frequency three-phase 380V~460V AC 50Hz/60Hz Input power supply: The voltage can vary by+10%, -15% of the rated input AC voltage Input power supply: The frequency allows for a variation of ± 5% of the rated input frequency Input power supply: Instantaneous voltage drop tolerance · Continue running above 323V AC · Continue running for 15ms when dropped below 323V AC Output frequency: Frequency range V/F Control: 0.2Hz~400Hz Sensorless vector control: 0.5Hz~120Hz Output frequency: Frequency display digital display
In StockNew Sealed Under Guarantee
AMK5002P24
Standard applicable motor output (kW) 0.75kW Rated output: rated voltage three-phase 380V~460V AC (power supply voltage ratio) Rated output: Overload current Rated standard load specification: 150% of rated output current for 1 minute Light load specification: 120% of rated output current for 1 minute Input power supply: Phase number, voltage, frequency three-phase 380V~460V AC 50Hz/60Hz Input power supply: The voltage can vary by+10%, -15% of the rated input AC voltage Input power supply: The frequency allows for a variation of ± 5% of the rated input frequency Input power supply: Instantaneous voltage drop tolerance · Continue running above 323V AC · Continue running for 15ms when dropped below 323V AC Output frequency: Frequency range V/F Control: 0.2Hz~400Hz Sensorless vector control: 0.5Hz~120Hz Output frequency: Frequency display digital display
In StockNew Sealed Under Guarantee
AMK5003P74
Standard applicable motor output (kW) 0.75kW Rated output: rated voltage three-phase 380V~460V AC (power supply voltage ratio) Rated output: Overload current Rated standard load specification: 150% of rated output current for 1 minute Light load specification: 120% of rated output current for 1 minute Input power supply: Phase number, voltage, frequency three-phase 380V~460V AC 50Hz/60Hz Input power supply: The voltage can vary by+10%, -15% of the rated input AC voltage Input power supply: The frequency allows for a variation of ± 5% of the rated input frequency Input power supply: Instantaneous voltage drop tolerance · Continue running above 323V AC · Continue running for 15ms when dropped below 323V AC Output frequency: Frequency range V/F Control: 0.2Hz~400Hz Sensorless vector control: 0.5Hz~120Hz Output frequency: Frequency display digital display
In StockNew Sealed Under Guarantee
AMK5005P54
Standard applicable motor output (kW) 0.75kW Rated output: rated voltage three-phase 380V~460V AC (power supply voltage ratio) Rated output: Overload current Rated standard load specification: 150% of rated output current for 1 minute Light load specification: 120% of rated output current for 1 minute Input power supply: Phase number, voltage, frequency three-phase 380V~460V AC 50Hz/60Hz Input power supply: The voltage can vary by+10%, -15% of the rated input AC voltage Input power supply: The frequency allows for a variation of ± 5% of the rated input frequency Input power supply: Instantaneous voltage drop tolerance · Continue running above 323V AC · Continue running for 15ms when dropped below 323V AC Output frequency: Frequency range V/F Control: 0.2Hz~400Hz Sensorless vector control: 0.5Hz~120Hz Output frequency: Frequency display digital display
In StockNew Sealed Under Guarantee
AMK5007P54
Standard applicable motor output (kW) 0.75kW Rated output: rated voltage three-phase 380V~460V AC (power supply voltage ratio) Rated output: Overload current Rated standard load specification: 150% of rated output current for 1 minute Light load specification: 120% of rated output current for 1 minute Input power supply: Phase number, voltage, frequency three-phase 380V~460V AC 50Hz/60Hz Input power supply: The voltage can vary by+10%, -15% of the rated input AC voltage Input power supply: The frequency allows for a variation of ± 5% of the rated input frequency Input power supply: Instantaneous voltage drop tolerance · Continue running above 323V AC · Continue running for 15ms when dropped below 323V AC Output frequency: Frequency range V/F Control: 0.2Hz~400Hz Sensorless vector control: 0.5Hz~120Hz Output frequency: Frequency display digital display
In StockNew Sealed Under Guarantee
AMK5000114
Standard applicable motor output (kW) 0.75kW Rated output: rated voltage three-phase 380V~460V AC (power supply voltage ratio) Rated output: Overload current Rated standard load specification: 150% of rated output current for 1 minute Light load specification: 120% of rated output current for 1 minute Input power supply: Phase number, voltage, frequency three-phase 380V~460V AC 50Hz/60Hz Input power supply: The voltage can vary by+10%, -15% of the rated input AC voltage Input power supply: The frequency allows for a variation of ± 5% of the rated input frequency Input power supply: Instantaneous voltage drop tolerance · Continue running above 323V AC · Continue running for 15ms when dropped below 323V AC Output frequency: Frequency range V/F Control: 0.2Hz~400Hz Sensorless vector control: 0.5Hz~120Hz Output frequency: Frequency display digital display
In StockNew Sealed Under Guarantee
PI150
PI150 0R4G1(Z)
In StockNew Sealed Under Guarantee
PI150 0R4G2(Z)
In StockNew Sealed Under Guarantee
PI150 0R7G1(Z)
In StockNew Sealed Under Guarantee
PI150 0R7G2(Z)
In StockNew Sealed Under Guarantee
P1150 0R7G3(Z)
In StockNew Sealed Under Guarantee
PI150 1R5G1(Z)
In StockNew Sealed Under Guarantee
PI150 1R5G2(Z)
In StockNew Sealed Under Guarantee
P1150 1R5G3(Z)
In StockNew Sealed Under Guarantee
P1150 2R2G3(Z)
In StockNew Sealed Under Guarantee
PI150 2R2G1(Z)
In StockNew Sealed Under Guarantee
P1150 2R2G2(Z)
In StockNew Sealed Under Guarantee
PI150 004G3(Z)
In StockNew Sealed Under Guarantee
PI150 5R5G3(Z)
In StockNew Sealed Under Guarantee
PI500-W
PI500-W 0R4G1
KEMATIONIn StockNew Sealed Under Guarantee
PI500-W 0R4G2
KEMATIONIn StockNew Sealed Under Guarantee
PI500-W 0R7G1
KEMATIONIn StockNew Sealed Under Guarantee
PI500-W 0R7G2
KEMATIONIn StockNew Sealed Under Guarantee
PI500-W 0R7G3
KEMATIONIn StockNew Sealed Under Guarantee
PI500-W 0R7G4
KEMATIONIn StockNew Sealed Under Guarantee
PI500-W 1R5G2
KEMATIONIn StockNew Sealed Under Guarantee
PI500-W 1R5G3
KEMATIONIn StockNew Sealed Under Guarantee
PI500-W 1R5G4
KEMATIONIn StockNew Sealed Under Guarantee
PI500-W 2R2G3
KEMATIONIn StockNew Sealed Under Guarantee
PI500-W 2R2G4
KEMATIONIn StockNew Sealed Under Guarantee
PI500-W 1R5G1
KEMATIONIn StockNew Sealed Under Guarantee
PI500-W 2R2G1
KEMATIONIn StockNew Sealed Under Guarantee
PI500-W 2R2G2
KEMATIONIn StockNew Sealed Under Guarantee
PI500-W 004G3
KEMATIONIn StockNew Sealed Under Guarantee
PI500-W 004G4
KEMATIONIn StockNew Sealed Under Guarantee
PI500-W 004G1
KEMATIONIn StockNew Sealed Under Guarantee
PI500-W 004G2
KEMATIONIn StockNew Sealed Under Guarantee
PI500-W 5R5G2
KEMATIONIn StockNew Sealed Under Guarantee
PI500-W 5R5G3
KEMATIONIn StockNew Sealed Under Guarantee
PI500A frequency converter
PI500A7R5G4
1)Environment temperature -10 ℃ to 50 ℃, temperature at 40 ℃, please derating for use, derating at 3% per 1°C drop. It is not recommended to use the inverter in the environment above 50°C. 2)Prevent electromagnetic interference and keep away from sources of interference. 3)Prevent intrusion of the water droplets, steam, dust, dust, cotton wool, and metal fines. 4)Prevent intrusion of the oil, salt, and corrosive gases. 5)Avoid vibrations. The maximum amplitude can’t exceed 5.9m/s (0.6g). 6)Avoid high temperature and humidity and no rain. Relative humidity is less than 90%RH. Do not allow condensation. In spaces where corrosive gases are present, the maximum relative humidity can’t exceed 60%. 7)Altitude 8)The use of flammable, flammable, explosive gas, liquid or solid hazardous environments is prohibited.
powtranIn StockNew Sealed Under Guarantee
PI500A011F4
1)Environment temperature -10 ℃ to 50 ℃, temperature at 40 ℃, please derating for use, derating at 3% per 1°C drop. It is not recommended to use the inverter in the environment above 50°C. 2)Prevent electromagnetic interference and keep away from sources of interference. 3)Prevent intrusion of the water droplets, steam, dust, dust, cotton wool, and metal fines. 4)Prevent intrusion of the oil, salt, and corrosive gases. 5)Avoid vibrations. The maximum amplitude can’t exceed 5.9m/s (0.6g). 6)Avoid high temperature and humidity and no rain. Relative humidity is less than 90%RH. Do not allow condensation. In spaces where corrosive gases are present, the maximum relative humidity can’t exceed 60%. 7)Altitude 8)The use of flammable, flammable, explosive gas, liquid or solid hazardous environments is prohibited.
powtranIn StockNew Sealed Under Guarantee
PI500A011G4
1)Environment temperature -10 ℃ to 50 ℃, temperature at 40 ℃, please derating for use, derating at 3% per 1°C drop. It is not recommended to use the inverter in the environment above 50°C. 2)Prevent electromagnetic interference and keep away from sources of interference. 3)Prevent intrusion of the water droplets, steam, dust, dust, cotton wool, and metal fines. 4)Prevent intrusion of the oil, salt, and corrosive gases. 5)Avoid vibrations. The maximum amplitude can’t exceed 5.9m/s (0.6g). 6)Avoid high temperature and humidity and no rain. Relative humidity is less than 90%RH. Do not allow condensation. In spaces where corrosive gases are present, the maximum relative humidity can’t exceed 60%. 7)Altitude 8)The use of flammable, flammable, explosive gas, liquid or solid hazardous environments is prohibited.
powtranIn StockNew Sealed Under Guarantee
PI500A015F4
1)Environment temperature -10 ℃ to 50 ℃, temperature at 40 ℃, please derating for use, derating at 3% per 1°C drop. It is not recommended to use the inverter in the environment above 50°C. 2)Prevent electromagnetic interference and keep away from sources of interference. 3)Prevent intrusion of the water droplets, steam, dust, dust, cotton wool, and metal fines. 4)Prevent intrusion of the oil, salt, and corrosive gases. 5)Avoid vibrations. The maximum amplitude can’t exceed 5.9m/s (0.6g). 6)Avoid high temperature and humidity and no rain. Relative humidity is less than 90%RH. Do not allow condensation. In spaces where corrosive gases are present, the maximum relative humidity can’t exceed 60%. 7)Altitude 8)The use of flammable, flammable, explosive gas, liquid or solid hazardous environments is prohibited.
powtranIn StockNew Sealed Under Guarantee
Pl500A015G4/018F4
1)Environment temperature -10 ℃ to 50 ℃, temperature at 40 ℃, please derating for use, derating at 3% per 1°C drop. It is not recommended to use the inverter in the environment above 50°C. 2)Prevent electromagnetic interference and keep away from sources of interference. 3)Prevent intrusion of the water droplets, steam, dust, dust, cotton wool, and metal fines. 4)Prevent intrusion of the oil, salt, and corrosive gases. 5)Avoid vibrations. The maximum amplitude can’t exceed 5.9m/s (0.6g). 6)Avoid high temperature and humidity and no rain. Relative humidity is less than 90%RH. Do not allow condensation. In spaces where corrosive gases are present, the maximum relative humidity can’t exceed 60%. 7)Altitude 8)The use of flammable, flammable, explosive gas, liquid or solid hazardous environments is prohibited.
powtranIn StockNew Sealed Under Guarantee
PI500A018G4/022F4
1)Environment temperature -10 ℃ to 50 ℃, temperature at 40 ℃, please derating for use, derating at 3% per 1°C drop. It is not recommended to use the inverter in the environment above 50°C. 2)Prevent electromagnetic interference and keep away from sources of interference. 3)Prevent intrusion of the water droplets, steam, dust, dust, cotton wool, and metal fines. 4)Prevent intrusion of the oil, salt, and corrosive gases. 5)Avoid vibrations. The maximum amplitude can’t exceed 5.9m/s (0.6g). 6)Avoid high temperature and humidity and no rain. Relative humidity is less than 90%RH. Do not allow condensation. In spaces where corrosive gases are present, the maximum relative humidity can’t exceed 60%. 7)Altitude 8)The use of flammable, flammable, explosive gas, liquid or solid hazardous environments is prohibited.
powtranIn StockNew Sealed Under Guarantee
PI500A0R4G1S
1)Environment temperature -10 ℃ to 50 ℃, temperature at 40 ℃, please derating for use, derating at 3% per 1°C drop. It is not recommended to use the inverter in the environment above 50°C. 2)Prevent electromagnetic interference and keep away from sources of interference. 3)Prevent intrusion of the water droplets, steam, dust, dust, cotton wool, and metal fines. 4)Prevent intrusion of the oil, salt, and corrosive gases. 5)Avoid vibrations. The maximum amplitude can’t exceed 5.9m/s (0.6g). 6)Avoid high temperature and humidity and no rain. Relative humidity is less than 90%RH. Do not allow condensation. In spaces where corrosive gases are present, the maximum relative humidity can’t exceed 60%. 7)Altitude 8)The use of flammable, flammable, explosive gas, liquid or solid hazardous environments is prohibited.
powtranIn StockNew Sealed Under Guarantee
PI500A0R7G1S
1)Environment temperature -10 ℃ to 50 ℃, temperature at 40 ℃, please derating for use, derating at 3% per 1°C drop. It is not recommended to use the inverter in the environment above 50°C. 2)Prevent electromagnetic interference and keep away from sources of interference. 3)Prevent intrusion of the water droplets, steam, dust, dust, cotton wool, and metal fines. 4)Prevent intrusion of the oil, salt, and corrosive gases. 5)Avoid vibrations. The maximum amplitude can’t exceed 5.9m/s (0.6g). 6)Avoid high temperature and humidity and no rain. Relative humidity is less than 90%RH. Do not allow condensation. In spaces where corrosive gases are present, the maximum relative humidity can’t exceed 60%. 7)Altitude 8)The use of flammable, flammable, explosive gas, liquid or solid hazardous environments is prohibited.
powtranIn StockNew Sealed Under Guarantee
PI500A1R5G1S
1)Environment temperature -10 ℃ to 50 ℃, temperature at 40 ℃, please derating for use, derating at 3% per 1°C drop. It is not recommended to use the inverter in the environment above 50°C. 2)Prevent electromagnetic interference and keep away from sources of interference. 3)Prevent intrusion of the water droplets, steam, dust, dust, cotton wool, and metal fines. 4)Prevent intrusion of the oil, salt, and corrosive gases. 5)Avoid vibrations. The maximum amplitude can’t exceed 5.9m/s (0.6g). 6)Avoid high temperature and humidity and no rain. Relative humidity is less than 90%RH. Do not allow condensation. In spaces where corrosive gases are present, the maximum relative humidity can’t exceed 60%. 7)Altitude 8)The use of flammable, flammable, explosive gas, liquid or solid hazardous environments is prohibited.
powtranIn StockNew Sealed Under Guarantee
PI500A2R2G1S
1)Environment temperature -10 ℃ to 50 ℃, temperature at 40 ℃, please derating for use, derating at 3% per 1°C drop. It is not recommended to use the inverter in the environment above 50°C. 2)Prevent electromagnetic interference and keep away from sources of interference. 3)Prevent intrusion of the water droplets, steam, dust, dust, cotton wool, and metal fines. 4)Prevent intrusion of the oil, salt, and corrosive gases. 5)Avoid vibrations. The maximum amplitude can’t exceed 5.9m/s (0.6g). 6)Avoid high temperature and humidity and no rain. Relative humidity is less than 90%RH. Do not allow condensation. In spaces where corrosive gases are present, the maximum relative humidity can’t exceed 60%. 7)Altitude 8)The use of flammable, flammable, explosive gas, liquid or solid hazardous environments is prohibited.
powtranIn StockNew Sealed Under Guarantee
PI500A004G1S
1)Environment temperature -10 ℃ to 50 ℃, temperature at 40 ℃, please derating for use, derating at 3% per 1°C drop. It is not recommended to use the inverter in the environment above 50°C. 2)Prevent electromagnetic interference and keep away from sources of interference. 3)Prevent intrusion of the water droplets, steam, dust, dust, cotton wool, and metal fines. 4)Prevent intrusion of the oil, salt, and corrosive gases. 5)Avoid vibrations. The maximum amplitude can’t exceed 5.9m/s (0.6g). 6)Avoid high temperature and humidity and no rain. Relative humidity is less than 90%RH. Do not allow condensation. In spaces where corrosive gases are present, the maximum relative humidity can’t exceed 60%. 7)Altitude 8)The use of flammable, flammable, explosive gas, liquid or solid hazardous environments is prohibited.
powtranIn StockNew Sealed Under Guarantee
PI500A5R5G1S
1)Environment temperature -10 ℃ to 50 ℃, temperature at 40 ℃, please derating for use, derating at 3% per 1°C drop. It is not recommended to use the inverter in the environment above 50°C. 2)Prevent electromagnetic interference and keep away from sources of interference. 3)Prevent intrusion of the water droplets, steam, dust, dust, cotton wool, and metal fines. 4)Prevent intrusion of the oil, salt, and corrosive gases. 5)Avoid vibrations. The maximum amplitude can’t exceed 5.9m/s (0.6g). 6)Avoid high temperature and humidity and no rain. Relative humidity is less than 90%RH. Do not allow condensation. In spaces where corrosive gases are present, the maximum relative humidity can’t exceed 60%. 7)Altitude 8)The use of flammable, flammable, explosive gas, liquid or solid hazardous environments is prohibited.
powtranIn StockNew Sealed Under Guarantee
PI500A 0R4G1
1)Environment temperature -10 ℃ to 50 ℃, temperature at 40 ℃, please derating for use, derating at 3% per 1°C drop. It is not recommended to use the inverter in the environment above 50°C. 2)Prevent electromagnetic interference and keep away from sources of interference. 3)Prevent intrusion of the water droplets, steam, dust, dust, cotton wool, and metal fines. 4)Prevent intrusion of the oil, salt, and corrosive gases. 5)Avoid vibrations. The maximum amplitude can’t exceed 5.9m/s (0.6g). 6)Avoid high temperature and humidity and no rain. Relative humidity is less than 90%RH. Do not allow condensation. In spaces where corrosive gases are present, the maximum relative humidity can’t exceed 60%. 7)Altitude 8)The use of flammable, flammable, explosive gas, liquid or solid hazardous environments is prohibited.
powtranIn StockNew Sealed Under Guarantee
PI500A 0R7G1
1)Environment temperature -10 ℃ to 50 ℃, temperature at 40 ℃, please derating for use, derating at 3% per 1°C drop. It is not recommended to use the inverter in the environment above 50°C. 2)Prevent electromagnetic interference and keep away from sources of interference. 3)Prevent intrusion of the water droplets, steam, dust, dust, cotton wool, and metal fines. 4)Prevent intrusion of the oil, salt, and corrosive gases. 5)Avoid vibrations. The maximum amplitude can’t exceed 5.9m/s (0.6g). 6)Avoid high temperature and humidity and no rain. Relative humidity is less than 90%RH. Do not allow condensation. In spaces where corrosive gases are present, the maximum relative humidity can’t exceed 60%. 7)Altitude 8)The use of flammable, flammable, explosive gas, liquid or solid hazardous environments is prohibited.
powtranIn StockNew Sealed Under Guarantee
PI500A 1R5G1
1)Environment temperature -10 ℃ to 50 ℃, temperature at 40 ℃, please derating for use, derating at 3% per 1°C drop. It is not recommended to use the inverter in the environment above 50°C. 2)Prevent electromagnetic interference and keep away from sources of interference. 3)Prevent intrusion of the water droplets, steam, dust, dust, cotton wool, and metal fines. 4)Prevent intrusion of the oil, salt, and corrosive gases. 5)Avoid vibrations. The maximum amplitude can’t exceed 5.9m/s (0.6g). 6)Avoid high temperature and humidity and no rain. Relative humidity is less than 90%RH. Do not allow condensation. In spaces where corrosive gases are present, the maximum relative humidity can’t exceed 60%. 7)Altitude 8)The use of flammable, flammable, explosive gas, liquid or solid hazardous environments is prohibited.
powtranIn StockNew Sealed Under Guarantee
PI500A 2R2G1
1)Environment temperature -10 ℃ to 50 ℃, temperature at 40 ℃, please derating for use, derating at 3% per 1°C drop. It is not recommended to use the inverter in the environment above 50°C. 2)Prevent electromagnetic interference and keep away from sources of interference. 3)Prevent intrusion of the water droplets, steam, dust, dust, cotton wool, and metal fines. 4)Prevent intrusion of the oil, salt, and corrosive gases. 5)Avoid vibrations. The maximum amplitude can’t exceed 5.9m/s (0.6g). 6)Avoid high temperature and humidity and no rain. Relative humidity is less than 90%RH. Do not allow condensation. In spaces where corrosive gases are present, the maximum relative humidity can’t exceed 60%. 7)Altitude 8)The use of flammable, flammable, explosive gas, liquid or solid hazardous environments is prohibited.
powtranIn StockNew Sealed Under Guarantee
PI500A 004G1
1)Environment temperature -10 ℃ to 50 ℃, temperature at 40 ℃, please derating for use, derating at 3% per 1°C drop. It is not recommended to use the inverter in the environment above 50°C. 2)Prevent electromagnetic interference and keep away from sources of interference. 3)Prevent intrusion of the water droplets, steam, dust, dust, cotton wool, and metal fines. 4)Prevent intrusion of the oil, salt, and corrosive gases. 5)Avoid vibrations. The maximum amplitude can’t exceed 5.9m/s (0.6g). 6)Avoid high temperature and humidity and no rain. Relative humidity is less than 90%RH. Do not allow condensation. In spaces where corrosive gases are present, the maximum relative humidity can’t exceed 60%. 7)Altitude 8)The use of flammable, flammable, explosive gas, liquid or solid hazardous environments is prohibited.
powtranIn StockNew Sealed Under Guarantee
PI500A 0R4G2
1)Environment temperature -10 ℃ to 50 ℃, temperature at 40 ℃, please derating for use, derating at 3% per 1°C drop. It is not recommended to use the inverter in the environment above 50°C. 2)Prevent electromagnetic interference and keep away from sources of interference. 3)Prevent intrusion of the water droplets, steam, dust, dust, cotton wool, and metal fines. 4)Prevent intrusion of the oil, salt, and corrosive gases. 5)Avoid vibrations. The maximum amplitude can’t exceed 5.9m/s (0.6g). 6)Avoid high temperature and humidity and no rain. Relative humidity is less than 90%RH. Do not allow condensation. In spaces where corrosive gases are present, the maximum relative humidity can’t exceed 60%. 7)Altitude 8)The use of flammable, flammable, explosive gas, liquid or solid hazardous environments is prohibited.
powtranIn StockNew Sealed Under Guarantee
PI500A 0R7G2
1)Environment temperature -10 ℃ to 50 ℃, temperature at 40 ℃, please derating for use, derating at 3% per 1°C drop. It is not recommended to use the inverter in the environment above 50°C. 2)Prevent electromagnetic interference and keep away from sources of interference. 3)Prevent intrusion of the water droplets, steam, dust, dust, cotton wool, and metal fines. 4)Prevent intrusion of the oil, salt, and corrosive gases. 5)Avoid vibrations. The maximum amplitude can’t exceed 5.9m/s (0.6g). 6)Avoid high temperature and humidity and no rain. Relative humidity is less than 90%RH. Do not allow condensation. In spaces where corrosive gases are present, the maximum relative humidity can’t exceed 60%. 7)Altitude 8)The use of flammable, flammable, explosive gas, liquid or solid hazardous environments is prohibited.
powtranIn StockNew Sealed Under Guarantee
PI500A 1R5G2
1)Environment temperature -10 ℃ to 50 ℃, temperature at 40 ℃, please derating for use, derating at 3% per 1°C drop. It is not recommended to use the inverter in the environment above 50°C. 2)Prevent electromagnetic interference and keep away from sources of interference. 3)Prevent intrusion of the water droplets, steam, dust, dust, cotton wool, and metal fines. 4)Prevent intrusion of the oil, salt, and corrosive gases. 5)Avoid vibrations. The maximum amplitude can’t exceed 5.9m/s (0.6g). 6)Avoid high temperature and humidity and no rain. Relative humidity is less than 90%RH. Do not allow condensation. In spaces where corrosive gases are present, the maximum relative humidity can’t exceed 60%. 7)Altitude 8)The use of flammable, flammable, explosive gas, liquid or solid hazardous environments is prohibited.
powtranIn StockNew Sealed Under Guarantee
PI500A-S/PI500-S/PI150-S
PI150-S 5R5G4
KEMATIONIn StockNew Sealed Under Guarantee
PI150-S 5R5G3
KEMATIONIn StockNew Sealed Under Guarantee
PI150-S 004G4
KEMATIONIn StockNew Sealed Under Guarantee
PI150-S 004G3
KEMATIONIn StockNew Sealed Under Guarantee
PI150-S 2R2G4
KEMATIONIn StockNew Sealed Under Guarantee
PI150-S 2R2G2
KEMATIONIn StockNew Sealed Under Guarantee
PI150-S 2R2G1
KEMATIONIn StockNew Sealed Under Guarantee
PI150-S 2R2G3
KEMATIONIn StockNew Sealed Under Guarantee
PI150-S 1R5G4
KEMATIONIn StockNew Sealed Under Guarantee
PI150-S 1R5G3
KEMATIONIn StockNew Sealed Under Guarantee
PI150-S 1R5G2
KEMATIONIn StockNew Sealed Under Guarantee
PI150-S 1R5G1
KEMATIONIn StockNew Sealed Under Guarantee
PI150-S 0R7G4
KEMATIONIn StockNew Sealed Under Guarantee
PI150-S 0R7G3
KEMATIONIn StockNew Sealed Under Guarantee
PI150-S 0R7G2
KEMATIONIn StockNew Sealed Under Guarantee
PI150-S 0R7G1
KEMATIONIn StockNew Sealed Under Guarantee
PI150-S 0R4G2
KEMATIONIn StockNew Sealed Under Guarantee
PI150-S 0R4G1
KEMATIONIn StockNew Sealed Under Guarantee
PI500A-S 5R5G1S
KEMATIONIn StockNew Sealed Under Guarantee
PI500A-S 004G1S
KEMATIONIn StockNew Sealed Under Guarantee
PI550
PI550 0R4G1
KEMATIONIn StockNew Sealed Under Guarantee
PI550 0R7G1
KEMATIONIn StockNew Sealed Under Guarantee
PI550 1R5G1
KEMATIONIn StockNew Sealed Under Guarantee
PI550 2R2G1
KEMATIONIn StockNew Sealed Under Guarantee
PI550 004G1
KEMATIONIn StockNew Sealed Under Guarantee
PI550 5R5G1
KEMATIONIn StockNew Sealed Under Guarantee
PI550 7R5G1
KEMATIONIn StockNew Sealed Under Guarantee
PI550 011G1
KEMATIONIn StockNew Sealed Under Guarantee
PI550 015G1
KEMATIONIn StockNew Sealed Under Guarantee
PI550 018G1
KEMATIONIn StockNew Sealed Under Guarantee
PI550 022G1
KEMATIONIn StockNew Sealed Under Guarantee
PI550 030G1
KEMATIONIn StockNew Sealed Under Guarantee
PI550 037G1
KEMATIONIn StockNew Sealed Under Guarantee
PI550 045G1
KEMATIONIn StockNew Sealed Under Guarantee
PI550 055G1
KEMATIONIn StockNew Sealed Under Guarantee
PI550 075G1
KEMATIONIn StockNew Sealed Under Guarantee
PI550 093G1
KEMATIONIn StockNew Sealed Under Guarantee
PI550 110G1
KEMATIONIn StockNew Sealed Under Guarantee
PI550 132G1
KEMATIONIn StockNew Sealed Under Guarantee
PI550 160G1
KEMATIONIn StockNew Sealed Under Guarantee
PR5300/PR5200+ series
PR5300 7R5G2
KEMATIONIn StockNew Sealed Under Guarantee
PR5300 011G2
KEMATIONIn StockNew Sealed Under Guarantee
PR5300 015G2
KEMATIONIn StockNew Sealed Under Guarantee
PR5300 018G2
KEMATIONIn StockNew Sealed Under Guarantee
PR5300 022G2
KEMATIONIn StockNew Sealed Under Guarantee
PR5300 030G2
KEMATIONIn StockNew Sealed Under Guarantee
PR5300 037G2
KEMATIONIn StockNew Sealed Under Guarantee
PR5300 045G2
KEMATIONIn StockNew Sealed Under Guarantee
PR5300 055G2
KEMATIONIn StockNew Sealed Under Guarantee
PR5300 075G2
KEMATIONIn StockNew Sealed Under Guarantee
PR5300 090G2
KEMATIONIn StockNew Sealed Under Guarantee
PR5300 115G2
KEMATIONIn StockNew Sealed Under Guarantee
PR5300 132G2
KEMATIONIn StockNew Sealed Under Guarantee
PR5300 160G2
KEMATIONIn StockNew Sealed Under Guarantee
PR5300 185G2
KEMATIONIn StockNew Sealed Under Guarantee
PR5300 200G2
KEMATIONIn StockNew Sealed Under Guarantee
PR5300 011G3
KEMATIONIn StockNew Sealed Under Guarantee
PR5300 015G3
KEMATIONIn StockNew Sealed Under Guarantee
PRS300 018G3
KEMATIONIn StockNew Sealed Under Guarantee
PR5300 022G3
KEMATIONIn StockNew Sealed Under Guarantee
Yaskawa frequency converter
CIMR-AB4A0044FBA
YASKAWAIn StockNew Sealed Under Guarantee
CIPR-GA70B4075ABBA
YASKAWAIn StockNew Sealed Under Guarantee
CIMR-VB4A0005BBA
YASKAWAIn StockNew Sealed Under Guarantee
CIMR-VB4A0018FBA
YASKAWAIn StockNew Sealed Under Guarantee
CIMR-VB4A0038FBA
YASKAWAIn StockNew Sealed Under Guarantee
CIMR-VB4A0023FBA
YASKAWAIn StockNew Sealed Under Guarantee
CIMR-VB4A0007BBA
YASKAWAIn StockNew Sealed Under Guarantee
CIMR-AB4A0007FBA
YASKAWAIn StockNew Sealed Under Guarantee
CIMR-VB4A0004BBA
YASKAWAIn StockNew Sealed Under Guarantee
CIMR-VBBA0003BBA
YASKAWAIn StockNew Sealed Under Guarantee
CIMR-VBBA0010BBA
YASKAWAIn StockNew Sealed Under Guarantee
CIMR-VBBA0012BBA
YASKAWAIn StockNew Sealed Under Guarantee
CIMR-VB4A0002BBA
YASKAWAIn StockNew Sealed Under Guarantee
CIMR-JB4A0009BBA
Two load ratings are used, one for light load (ND) and one for heavy load (HD). Parameters can be set simply according to the type of machinery. If ND is selected, it can be used for motors with large capacity. It is small in size and can be arranged side by side to reduce the volume of the control cabinetSimple designThe small size and side-by-side installation reduce the size of the control cabinet. Simple operationIn the parameter setting mode, parameters can be set simply. The verification function can simply confirm that the factory set parameters have been changed. Care for the environmentStandard products comply with the RoHS) directive. The Swing PWM method, which can suppress electromagnetic noise, can solve the problem of harsh sound. Support stable operationIt can be easily operated even under heavy loadWhen the whole field and automatic torque increase operation is carried out, whether it is acceleration and deceleration or constant speed, high torque will be generated. It can continue to operate even if the load or power supply changes or there is an instantaneous power failure. The full stall prevention function and speed search function can prevent the frequency converter from stopping and continue to run. Full braking functionDue to the over-excitation braking function, emergency braking can be achieved even without a braking resistor.
YASKAWAIn StockNew Sealed Under Guarantee
CIMR-VB4A0009BBA
YASKAWAIn StockNew Sealed Under Guarantee
CIMR-AB4A0058FBA
YASKAWAIn StockNew Sealed Under Guarantee
CIPR-GA70B4089ABBA
YASKAWAIn StockNew Sealed Under Guarantee
CIPR-GA70B4168ABBA
YASKAWAIn StockNew Sealed Under Guarantee
CIMR-VB2A0004BBA
YASKAWAIn StockNew Sealed Under Guarantee
CIMR-VB4A0031FBA
YASKAWAIn StockNew Sealed Under Guarantee
1.362754s