• KEYENCE

  • Newest
  • Most reviews
ModelDescriptionBrandLeadingConditionPriceAction
Fiber Sensors
FX-501
Applicable regulations and certifications CE Marking (EMC Directive, RoHS Directive)UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Listing certificationSupply voltage 12 to 24 V DC+10-15 % Ripple P-P 10 % or lessPower consumption Normal operation: 960 mW or less (current consumption 40 mA or less at 24 V supply voltage)ECO mode: 680 mW or less (current consumption 28 mA or less at 24 V supply voltage)Output NPN open-collector transistor- Maximum sink current: 100 mA (Note 1)- Applied voltage: 30 V DC or less (between output and 0 V)- Residual voltage: 2 V or less (Note 2) (at maximum sink current)(Note 1) 50 mA max. if 5 or more standard types are connected together.(Note 2) 50 mA max. if 5 or more standard types are connected together. (25 mA in case of 2-output type and cable type)Output:Output points 1 pointOutput:Output operation Switchable either Light-ON or Dark-ON by L/D mode
In StockNew Sealed Under Guarantee
FX-502
Applicable regulations and certifications CE Marking (EMC Directive, RoHS Directive)UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Listing certificationSupply voltage 12 to 24 V DC+10-15 % Ripple P-P 10 % or lessPower consumption Normal operation: 960 mW or less (current consumption 40 mA or less at 24 V supply voltage)ECO mode: 680 mW or less (current consumption 28 mA or less at 24 V supply voltage)Output NPN open-collector transistor- Maximum sink current: 100 mA (Note 1)- Applied voltage: 30 V DC or less (between output and 0 V)- Residual voltage: 2 V or less (Note 2) (at maximum sink current)(Note 1) 50 mA max. if 5 or more standard types are connected together.(Note 2) 50 mA max. if 5 or more standard types are connected together. (25 mA in case of 2-output type and cable type)Output:Output points 1 pointOutput:Output operation Switchable either Light-ON or Dark-ON by L/D mode
In StockNew Sealed Under Guarantee
FX-505-C2
Applicable regulations and certifications CE Marking (EMC Directive, RoHS Directive)UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Listing certificationSupply voltage 12 to 24 V DC+10-15 % Ripple P-P 10 % or lessPower consumption Normal operation: 960 mW or less (current consumption 40 mA or less at 24 V supply voltage)ECO mode: 680 mW or less (current consumption 28 mA or less at 24 V supply voltage)Output NPN open-collector transistor- Maximum sink current: 100 mA (Note 1)- Applied voltage: 30 V DC or less (between output and 0 V)- Residual voltage: 2 V or less (Note 2) (at maximum sink current)(Note 1) 50 mA max. if 5 or more standard types are connected together.(Note 2) 50 mA max. if 5 or more standard types are connected together. (25 mA in case of 2-output type and cable type)Output:Output points 1 pointOutput:Output operation Switchable either Light-ON or Dark-ON by L/D mode
In StockNew Sealed Under Guarantee
FX-102P
Applicable regulations and certifications CE Marking (EMC Directive, RoHS Directive) UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Listing certification Supply voltage 12 to 24 V DC+10-15 % Ripple P-P 10 % or less Power consumption Normal operation: 960 mW or less (current consumption 40 mA or less at 24 V supply voltage) ECO mode: 680 mW or less (current consumption 28 mA or less at 24 V supply voltage) Output NPN open-collector transistor - Maximum sink current: 100 mA (Note 1) - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 2 V or less (Note 2) (at maximum sink current) (Note 1) 50 mA max. if 5 or more standard types are connected together. (Note 2) 50 mA max. if 5 or more standard types are connected together. (25 mA in case of 2-output type and cable type) Output:Output points 1 point Output:Output operation Switchable either Light-ON or Dark-ON by L/D mode
In StockNew Sealed Under Guarantee
FD-S30
In StockNew Sealed Under Guarantee
FD-R60
In StockNew Sealed Under Guarantee
FD-V50
In StockNew Sealed Under Guarantee
FT-Z20W
As of November 23, 2023Specifications and design of the products are subject to change without notice for the product improvement. Spec Detail Item Specifications Product Number FT-Z20W Part Number FT-Z20W Sensing mode Thru-beam type Fiber type Flat type, with boss Fiber head length W10 x H7 x D2 mm With sleeve No Beam direction Front sensing Beam axis dia./ Spot diameter dia. 1.5 mm Fiber cable length 1 m Allowable bending radius R1 mm Free-cut Available Semi-custom Fiber length change Mounting lens Not available Mounting protective tube Not available Application General-purpose Environmental resistance : Protection IP40 Environmental resistance : Ambient temperature MAX 60 degrees Environmental resistance : Ambient temperature MIN -40 degrees Sensing range(STD) 620 mm 24.409 in (FX-500 series) Sensing range(HYPR) 1,600 mm 62.992 in (FX-500 series) Sensing range(U-LG) 1,500 mm 59.055 in (FX-500 series) Sensing range(LONG) 1,100 mm 43.307 in (FX-500 series) Sensing range(FAST) 420 mm 16.535 in (FX-500 series) Sensing range(H-SP) 130 mm 5.118 in (FX-500 series) Dimensions Accessories (Option) Return to top
In StockNew Sealed Under Guarantee
FT-Z40HBW
In StockNew Sealed Under Guarantee
FT-KV26H1
In StockNew Sealed Under Guarantee
FD-AL11
In StockNew Sealed Under Guarantee
FD-L12W
In StockNew Sealed Under Guarantee
FX-501P
Applicable regulations and certifications CE Marking (EMC Directive, RoHS Directive) UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Listing certification Supply voltage 12 to 24 V DC+10-15 % Ripple P-P 10 % or less Power consumption Normal operation: 960 mW or less (current consumption 40 mA or less at 24 V supply voltage) ECO mode: 680 mW or less (current consumption 28 mA or less at 24 V supply voltage) Output NPN open-collector transistor - Maximum sink current: 100 mA (Note 1) - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 2 V or less (Note 2) (at maximum sink current) (Note 1) 50 mA max. if 5 or more standard types are connected together. (Note 2) 50 mA max. if 5 or more standard types are connected together. (25 mA in case of 2-output type and cable type) Output:Output points 1 point Output:Output operation Switchable either Light-ON or Dark-ON by L/D mode
In StockNew Sealed Under Guarantee
FX-502P
Applicable regulations and certifications CE Marking (EMC Directive, RoHS Directive) UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Listing certification Supply voltage 12 to 24 V DC+10-15 % Ripple P-P 10 % or less Power consumption Normal operation: 960 mW or less (current consumption 40 mA or less at 24 V supply voltage) ECO mode: 680 mW or less (current consumption 28 mA or less at 24 V supply voltage) Output NPN open-collector transistor - Maximum sink current: 100 mA (Note 1) - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 2 V or less (Note 2) (at maximum sink current) (Note 1) 50 mA max. if 5 or more standard types are connected together. (Note 2) 50 mA max. if 5 or more standard types are connected together. (25 mA in case of 2-output type and cable type) Output:Output points 1 point Output:Output operation Switchable either Light-ON or Dark-ON by L/D mode
In StockNew Sealed Under Guarantee
FX-505P-C2
Applicable regulations and certifications CE Marking (EMC Directive, RoHS Directive) UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Listing certification Supply voltage 12 to 24 V DC+10-15 % Ripple P-P 10 % or less Power consumption Normal operation: 960 mW or less (current consumption 40 mA or less at 24 V supply voltage) ECO mode: 680 mW or less (current consumption 28 mA or less at 24 V supply voltage) Output NPN open-collector transistor - Maximum sink current: 100 mA (Note 1) - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 2 V or less (Note 2) (at maximum sink current) (Note 1) 50 mA max. if 5 or more standard types are connected together. (Note 2) 50 mA max. if 5 or more standard types are connected together. (25 mA in case of 2-output type and cable type) Output:Output points 1 point Output:Output operation Switchable either Light-ON or Dark-ON by L/D mode
In StockNew Sealed Under Guarantee
FX-551
Applicable regulations and certifications CE Marking (EMC Directive, RoHS Directive) UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Listing certification Supply voltage 12 to 24 V DC+10-15 % Ripple P-P 10 % or less Power consumption Normal operation: 960 mW or less (current consumption 40 mA or less at 24 V supply voltage) ECO mode: 680 mW or less (current consumption 28 mA or less at 24 V supply voltage) Output NPN open-collector transistor - Maximum sink current: 100 mA (Note 1) - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 2 V or less (Note 2) (at maximum sink current) (Note 1) 50 mA max. if 5 or more standard types are connected together. (Note 2) 50 mA max. if 5 or more standard types are connected together. (25 mA in case of 2-output type and cable type) Output:Output points 1 point Output:Output operation Switchable either Light-ON or Dark-ON by L/D mode
In StockNew Sealed Under Guarantee
FX-551P
Applicable regulations and certifications CE Marking (EMC Directive, RoHS Directive) UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Listing certification Supply voltage 12 to 24 V DC+10-15 % Ripple P-P 10 % or less Power consumption Normal operation: 960 mW or less (current consumption 40 mA or less at 24 V supply voltage) ECO mode: 680 mW or less (current consumption 28 mA or less at 24 V supply voltage) Output NPN open-collector transistor - Maximum sink current: 100 mA (Note 1) - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 2 V or less (Note 2) (at maximum sink current) (Note 1) 50 mA max. if 5 or more standard types are connected together. (Note 2) 50 mA max. if 5 or more standard types are connected together. (25 mA in case of 2-output type and cable type) Output:Output points 1 point Output:Output operation Switchable either Light-ON or Dark-ON by L/D mode
In StockNew Sealed Under Guarantee
FX-551-C2
Applicable regulations and certifications CE Marking (EMC Directive, RoHS Directive) UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Listing certification Supply voltage 12 to 24 V DC+10-15 % Ripple P-P 10 % or less Power consumption Normal operation: 960 mW or less (current consumption 40 mA or less at 24 V supply voltage) ECO mode: 680 mW or less (current consumption 28 mA or less at 24 V supply voltage) Output NPN open-collector transistor - Maximum sink current: 100 mA (Note 1) - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 2 V or less (Note 2) (at maximum sink current) (Note 1) 50 mA max. if 5 or more standard types are connected together. (Note 2) 50 mA max. if 5 or more standard types are connected together. (25 mA in case of 2-output type and cable type) Output:Output points 1 point Output:Output operation Switchable either Light-ON or Dark-ON by L/D mode
In StockNew Sealed Under Guarantee
FX-551P-C2
Applicable regulations and certifications CE Marking (EMC Directive, RoHS Directive) UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Listing certification Supply voltage 12 to 24 V DC+10-15 % Ripple P-P 10 % or less Power consumption Normal operation: 960 mW or less (current consumption 40 mA or less at 24 V supply voltage) ECO mode: 680 mW or less (current consumption 28 mA or less at 24 V supply voltage) Output NPN open-collector transistor - Maximum sink current: 100 mA (Note 1) - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 2 V or less (Note 2) (at maximum sink current) (Note 1) 50 mA max. if 5 or more standard types are connected together. (Note 2) 50 mA max. if 5 or more standard types are connected together. (25 mA in case of 2-output type and cable type) Output:Output points 1 point Output:Output operation Switchable either Light-ON or Dark-ON by L/D mode
In StockNew Sealed Under Guarantee
FX-101
Applicable regulations and certifications CE Marking (EMC Directive, RoHS Directive) UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Listing certification Supply voltage 12 to 24 V DC+10-15 % Ripple P-P 10 % or less Power consumption Normal operation: 960 mW or less (current consumption 40 mA or less at 24 V supply voltage) ECO mode: 680 mW or less (current consumption 28 mA or less at 24 V supply voltage) Output NPN open-collector transistor - Maximum sink current: 100 mA (Note 1) - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 2 V or less (Note 2) (at maximum sink current) (Note 1) 50 mA max. if 5 or more standard types are connected together. (Note 2) 50 mA max. if 5 or more standard types are connected together. (25 mA in case of 2-output type and cable type) Output:Output points 1 point Output:Output operation Switchable either Light-ON or Dark-ON by L/D mode
In StockNew Sealed Under Guarantee
Particular Use Sensors
BE-A401P
Product Number BE-A201 Part Number BE-A201 Detectable air gap 0.8 mm 0.032 in or more (Note) Sensing air gap refers to the width of an air bubble formed in the entire area of the inner diameter of the tube. Please note that this product cannot sense very small air bubbles or water drops. Sensing object Liquid (Note) Sensing is affected by dirt or residues adhered to the inner wall of the tube. Please maintain the tube regularly. Applicable tube dia. (OD×ID) ø2 mm × ø1 mm ø0.078 in × ø0.039 in (Note) When using a tube out of specifications or it doesn't have a smooth surface, please test sensing on the actual machine before use. Applicable tube type Transparent resin tube (equivalent to PFA) (Note) When using a tube out of specifications or it doesn't have a smooth surface, please test sensing on the actual machine before use. Supply voltage 5 to 24 V DC ±10 % Ripple P-P 10 % or less Current consumption 15 mA or less Output (Incorporated with 2 outputs) NPN open-collector transistor •Maximum sink current: 50 mA •Applied voltage: 30 V DC or less (between output and 0 V) •Residual voltage: 2 V or less (sink current at 50 mA) 1 V or less (sink current at 16 mA) Output (Incorporated with 2 outputs):Output operation Switchable either Liquid-absent-ON or Liquid-present-ON
In StockNew Sealed Under Guarantee
HD-T1C
Sensing width 30 mm 1.181 in (Linearity is specified at 28 mm 1.102 in width.) Sensing range 30 mm 1.181 in (fixed) (Note 2) Pollution degree 3 (Industrial environment) Ambient temperature 0 to +40 ℃ +32 to +104℉ (No dew condensation), Storage: -20 to +55 ℃ -4 to +131℉ Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH Ambient illuminance Incandescent light: 3,000 lx at the light-receiving face, Fluorescent light: 3,000 lx at the light-receiving face Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each Shock resistance 490 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each Emitting element Red LED (Peak emission wavelength: 650 nm 0.026 mil) Receiving element Photodiode
In StockNew Sealed Under Guarantee
SQ4-A22-N
Sensing object Water (Standard liquid) (Note 1) Highly viscous liquid may not be stably detected. (Note 2) The agents mentioned above are examples. It may not be detected depending on viscosity the agent. Before using this device, check the detecting liquid and installation condition. Power voltage 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less Current consumption 30 mA or less Utilization category DC-12, DC-13 Detection output(Leakage detection) PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: Same as the supply voltage (between detection output and +V) - Residual voltage: 2.5 V or less (at 50 mA source current) Detection output(Leakage detection):Response time 10 ms or less Detection output(Leakage detection):Output operation ON when normal condition or initial detection, OFF when detection leakage or wrong installation
In StockNew Sealed Under Guarantee
EX-F62-PN-C5
Sensing object Agent, such as Water, Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. Note : Highly viscous liquid may not be detected stably. Note : The agents mentioned above are examples. For details, please contact our office. Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office. Supply voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less Current consumption 15 mA or less Output NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 23 mA sink current) Output:Output operation In normal state: ON, When leak detected or the sensor is mounted improperly: OFF
In StockNew Sealed Under Guarantee
EX-F1-C5
Sensing object Agent, such as Water, Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. Note : Highly viscous liquid may not be detected stably. Note : The agents mentioned above are examples. For details, please contact our office. Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office. Supply voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less Current consumption 15 mA or less Output NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 25 mA sink current) Output:Output operation In normal state: ON, When leak detected or the sensor is mounted improperly: OFF
In StockNew Sealed Under Guarantee
EZ-11-PN
Sensing range 5 m 16.404 ft (without container or pipe) (Note):The sensing range shortens depending on the thickness, material, color, etc., of the container or pipe. Sensing object ø12 mm ø0.472 mm or more liquid which contains water, or opaque object (Note):If there are two slit masks on both sides, the size of those slit masks represents the min. sensing object. Supply voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less Current consumption Emitter: 25 mA or less, Receiver: 25 mA or less Output NPN open-collector transistor ・Maximum sink current: 100 mA ・Applied voltage: 30 V DC or less (between output and 0 V) ・Residual voltage: 1.5 V or less (at 100 mA sink current) 0.4 V or less (at 16 mA sink current) Output:Utilization category DC-12 or DC-13 Output:Output operation Switchable either Light-ON or Dark-ON Output:Short-circuit protection Switchable either Light-ON or Dark-ON Response time 12 ms or less
In StockNew Sealed Under Guarantee
FD-L54
In StockNew Sealed Under Guarantee
LX-101-P-Z
In StockNew Sealed Under Guarantee
BE-A201
Product Number BE-A201 Part Number BE-A201 Detectable air gap 0.8 mm 0.032 in or more (Note) Sensing air gap refers to the width of an air bubble formed in the entire area of the inner diameter of the tube. Please note that this product cannot sense very small air bubbles or water drops. Sensing object Liquid (Note) Sensing is affected by dirt or residues adhered to the inner wall of the tube. Please maintain the tube regularly. Applicable tube dia. (OD×ID) ø2 mm × ø1 mm ø0.078 in × ø0.039 in (Note) When using a tube out of specifications or it doesn't have a smooth surface, please test sensing on the actual machine before use. Applicable tube type Transparent resin tube (equivalent to PFA) (Note) When using a tube out of specifications or it doesn't have a smooth surface, please test sensing on the actual machine before use. Supply voltage 5 to 24 V DC ±10 % Ripple P-P 10 % or less Current consumption 15 mA or less Output (Incorporated with 2 outputs) NPN open-collector transistor •Maximum sink current: 50 mA •Applied voltage: 30 V DC or less (between output and 0 V) •Residual voltage: 2 V or less (sink current at 50 mA) 1 V or less (sink current at 16 mA) Output (Incorporated with 2 outputs):Output operation Switchable either Liquid-absent-ON or Liquid-present-ON
In StockNew Sealed Under Guarantee
BE-A201P
Product Number BE-A201 Part Number BE-A201 Detectable air gap 0.8 mm 0.032 in or more (Note) Sensing air gap refers to the width of an air bubble formed in the entire area of the inner diameter of the tube. Please note that this product cannot sense very small air bubbles or water drops. Sensing object Liquid (Note) Sensing is affected by dirt or residues adhered to the inner wall of the tube. Please maintain the tube regularly. Applicable tube dia. (OD×ID) ø2 mm × ø1 mm ø0.078 in × ø0.039 in (Note) When using a tube out of specifications or it doesn't have a smooth surface, please test sensing on the actual machine before use. Applicable tube type Transparent resin tube (equivalent to PFA) (Note) When using a tube out of specifications or it doesn't have a smooth surface, please test sensing on the actual machine before use. Supply voltage 5 to 24 V DC ±10 % Ripple P-P 10 % or less Current consumption 15 mA or less Output (Incorporated with 2 outputs) NPN open-collector transistor •Maximum sink current: 50 mA •Applied voltage: 30 V DC or less (between output and 0 V) •Residual voltage: 2 V or less (sink current at 50 mA) 1 V or less (sink current at 16 mA) Output (Incorporated with 2 outputs):Output operation Switchable either Liquid-absent-ON or Liquid-present-ON
In StockNew Sealed Under Guarantee
BE-A301
Product Number BE-A201 Part Number BE-A201 Detectable air gap 0.8 mm 0.032 in or more (Note) Sensing air gap refers to the width of an air bubble formed in the entire area of the inner diameter of the tube. Please note that this product cannot sense very small air bubbles or water drops. Sensing object Liquid (Note) Sensing is affected by dirt or residues adhered to the inner wall of the tube. Please maintain the tube regularly. Applicable tube dia. (OD×ID) ø2 mm × ø1 mm ø0.078 in × ø0.039 in (Note) When using a tube out of specifications or it doesn't have a smooth surface, please test sensing on the actual machine before use. Applicable tube type Transparent resin tube (equivalent to PFA) (Note) When using a tube out of specifications or it doesn't have a smooth surface, please test sensing on the actual machine before use. Supply voltage 5 to 24 V DC ±10 % Ripple P-P 10 % or less Current consumption 15 mA or less Output (Incorporated with 2 outputs) NPN open-collector transistor •Maximum sink current: 50 mA •Applied voltage: 30 V DC or less (between output and 0 V) •Residual voltage: 2 V or less (sink current at 50 mA) 1 V or less (sink current at 16 mA) Output (Incorporated with 2 outputs):Output operation Switchable either Liquid-absent-ON or Liquid-present-ON
In StockNew Sealed Under Guarantee
BE-A301P
Product Number BE-A201 Part Number BE-A201 Detectable air gap 0.8 mm 0.032 in or more (Note) Sensing air gap refers to the width of an air bubble formed in the entire area of the inner diameter of the tube. Please note that this product cannot sense very small air bubbles or water drops. Sensing object Liquid (Note) Sensing is affected by dirt or residues adhered to the inner wall of the tube. Please maintain the tube regularly. Applicable tube dia. (OD×ID) ø2 mm × ø1 mm ø0.078 in × ø0.039 in (Note) When using a tube out of specifications or it doesn't have a smooth surface, please test sensing on the actual machine before use. Applicable tube type Transparent resin tube (equivalent to PFA) (Note) When using a tube out of specifications or it doesn't have a smooth surface, please test sensing on the actual machine before use. Supply voltage 5 to 24 V DC ±10 % Ripple P-P 10 % or less Current consumption 15 mA or less Output (Incorporated with 2 outputs) NPN open-collector transistor •Maximum sink current: 50 mA •Applied voltage: 30 V DC or less (between output and 0 V) •Residual voltage: 2 V or less (sink current at 50 mA) 1 V or less (sink current at 16 mA) Output (Incorporated with 2 outputs):Output operation Switchable either Liquid-absent-ON or Liquid-present-ON
In StockNew Sealed Under Guarantee
BE-A401
Product Number BE-A201 Part Number BE-A201 Detectable air gap 0.8 mm 0.032 in or more (Note) Sensing air gap refers to the width of an air bubble formed in the entire area of the inner diameter of the tube. Please note that this product cannot sense very small air bubbles or water drops. Sensing object Liquid (Note) Sensing is affected by dirt or residues adhered to the inner wall of the tube. Please maintain the tube regularly. Applicable tube dia. (OD×ID) ø2 mm × ø1 mm ø0.078 in × ø0.039 in (Note) When using a tube out of specifications or it doesn't have a smooth surface, please test sensing on the actual machine before use. Applicable tube type Transparent resin tube (equivalent to PFA) (Note) When using a tube out of specifications or it doesn't have a smooth surface, please test sensing on the actual machine before use. Supply voltage 5 to 24 V DC ±10 % Ripple P-P 10 % or less Current consumption 15 mA or less Output (Incorporated with 2 outputs) NPN open-collector transistor •Maximum sink current: 50 mA •Applied voltage: 30 V DC or less (between output and 0 V) •Residual voltage: 2 V or less (sink current at 50 mA) 1 V or less (sink current at 16 mA) Output (Incorporated with 2 outputs):Output operation Switchable either Liquid-absent-ON or Liquid-present-ON
In StockNew Sealed Under Guarantee
HD-T1030
Sensing width 30 mm 1.181 in (Linearity is specified at 28 mm 1.102 in width.) Sensing range 30 mm 1.181 in (fixed) (Note 2) Pollution degree 3 (Industrial environment) Ambient temperature 0 to +40 ℃ +32 to +104℉ (No dew condensation), Storage: -20 to +55 ℃ -4 to +131℉ Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH Ambient illuminance Incandescent light: 3,000 lx at the light-receiving face, Fluorescent light: 3,000 lx at the light-receiving face Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each Shock resistance 490 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each Emitting element Red LED (Peak emission wavelength: 650 nm 0.026 mil) Receiving element Photodiode
In StockNew Sealed Under Guarantee
SQ4-A21-P
Sensing object Water (Standard liquid) (Note 1) Highly viscous liquid may not be stably detected. (Note 2) The agents mentioned above are examples. It may not be detected depending on viscosity the agent. Before using this device, check the detecting liquid and installation condition. Power voltage 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less Current consumption 30 mA or less Utilization category DC-12, DC-13 Detection output(Leakage detection) PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: Same as the supply voltage (between detection output and +V) - Residual voltage: 2.5 V or less (at 50 mA source current) Detection output(Leakage detection):Response time 10 ms or less Detection output(Leakage detection):Output operation ON when normal condition or initial detection, OFF when detection leakage or wrong installation
In StockNew Sealed Under Guarantee
SQ4-A21-N
Sensing object Water (Standard liquid) (Note 1) Highly viscous liquid may not be stably detected. (Note 2) The agents mentioned above are examples. It may not be detected depending on viscosity the agent. Before using this device, check the detecting liquid and installation condition. Power voltage 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less Current consumption 30 mA or less Utilization category DC-12, DC-13 Detection output(Leakage detection) PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: Same as the supply voltage (between detection output and +V) - Residual voltage: 2.5 V or less (at 50 mA source current) Detection output(Leakage detection):Response time 10 ms or less Detection output(Leakage detection):Output operation ON when normal condition or initial detection, OFF when detection leakage or wrong installation
In StockNew Sealed Under Guarantee
SQ4-A22-P
Sensing object Water (Standard liquid) (Note 1) Highly viscous liquid may not be stably detected. (Note 2) The agents mentioned above are examples. It may not be detected depending on viscosity the agent. Before using this device, check the detecting liquid and installation condition. Power voltage 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less Current consumption 30 mA or less Utilization category DC-12, DC-13 Detection output(Leakage detection) PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: Same as the supply voltage (between detection output and +V) - Residual voltage: 2.5 V or less (at 50 mA source current) Detection output(Leakage detection):Response time 10 ms or less Detection output(Leakage detection):Output operation ON when normal condition or initial detection, OFF when detection leakage or wrong installation
In StockNew Sealed Under Guarantee
EX-F61
Sensing object Agent, such as Water, Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. Note : Highly viscous liquid may not be detected stably. Note : The agents mentioned above are examples. For details, please contact our office. Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office. Supply voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less Current consumption 15 mA or less Output NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 16 mA sink current) Output:Output operation In normal state: ON, When leak detected or the sensor is mounted improperly: OFF
In StockNew Sealed Under Guarantee
EX-F61-PN
Sensing object Agent, such as Water, Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. Note : Highly viscous liquid may not be detected stably. Note : The agents mentioned above are examples. For details, please contact our office. Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office. Supply voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less Current consumption 15 mA or less Output NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 17 mA sink current) Output:Output operation In normal state: ON, When leak detected or the sensor is mounted improperly: OFF
In StockNew Sealed Under Guarantee
EX-F62
Sensing object Agent, such as Water, Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. Note : Highly viscous liquid may not be detected stably. Note : The agents mentioned above are examples. For details, please contact our office. Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office. Supply voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less Current consumption 15 mA or less Output NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 18 mA sink current) Output:Output operation In normal state: ON, When leak detected or the sensor is mounted improperly: OFF
In StockNew Sealed Under Guarantee
Laser Sensor
HG-SC101-P
In StockNew Sealed Under Guarantee
LS-501P
Regulatory compliance EMC Directive, RoHS Directive Applicable amplifiers LS-501(P), LS-501(P)-C2 (Note:When using the thru-beam type LS-H101□ or LS-H102□, do not set the receiving light sensitivity (gctL) of the applicable LS-500 series amplifier to level 2 or less. This is because there is a possibility of sensing becoming unstable.) Sensing range:H-SP mode 1m 3.281 ft (Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.) (Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.)
In StockNew Sealed Under Guarantee
EX-L291-P
In StockNew Sealed Under Guarantee
EX-L261-P
In StockNew Sealed Under Guarantee
EX-L262-P
In StockNew Sealed Under Guarantee
HG-C1400
In StockNew Sealed Under Guarantee
HG-C1030
In StockNew Sealed Under Guarantee
HG-C1050
In StockNew Sealed Under Guarantee
HG-C1100
In StockNew Sealed Under Guarantee
HG-C1200
In StockNew Sealed Under Guarantee
HG-C1030-P
In StockNew Sealed Under Guarantee
HG-C1050L-P
In StockNew Sealed Under Guarantee
HG-C1200-P
In StockNew Sealed Under Guarantee
HG-SC113
In StockNew Sealed Under Guarantee
HG-SC101
In StockNew Sealed Under Guarantee
LS-H101
Regulatory compliance EMC Directive, RoHS Directive Applicable amplifiers LS-501(P), LS-501(P)-C2 (Note:When using the thru-beam type LS-H101□ or LS-H102□, do not set the receiving light sensitivity (gctL) of the applicable LS-500 series amplifier to level 2 or less. This is because there is a possibility of sensing becoming unstable.) Sensing range:H-SP mode 1m 3.281 ft (Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.) (Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.)
In StockNew Sealed Under Guarantee
LS-H102
Regulatory compliance EMC Directive, RoHS Directive Applicable amplifiers LS-501(P), LS-501(P)-C2 (Note:When using the thru-beam type LS-H101□ or LS-H102□, do not set the receiving light sensitivity (gctL) of the applicable LS-500 series amplifier to level 2 or less. This is because there is a possibility of sensing becoming unstable.) Sensing range:H-SP mode 1m 3.281 ft (Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.) (Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.)
In StockNew Sealed Under Guarantee
LS-H901
Regulatory compliance EMC Directive, RoHS Directive Applicable amplifiers LS-501(P), LS-501(P)-C2 (Note:When using the thru-beam type LS-H101□ or LS-H102□, do not set the receiving light sensitivity (gctL) of the applicable LS-500 series amplifier to level 2 or less. This is because there is a possibility of sensing becoming unstable.) Sensing range:H-SP mode 1m 3.281 ft (Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.) (Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.)
In StockNew Sealed Under Guarantee
LS-H201
Regulatory compliance EMC Directive, RoHS Directive Applicable amplifiers LS-501(P), LS-501(P)-C2 (Note:When using the thru-beam type LS-H101□ or LS-H102□, do not set the receiving light sensitivity (gctL) of the applicable LS-500 series amplifier to level 2 or less. This is because there is a possibility of sensing becoming unstable.) Sensing range:H-SP mode 1m 3.281 ft (Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.) (Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.)
In StockNew Sealed Under Guarantee
LS-501
Regulatory compliance EMC Directive, RoHS Directive Applicable amplifiers LS-501(P), LS-501(P)-C2 (Note:When using the thru-beam type LS-H101□ or LS-H102□, do not set the receiving light sensitivity (gctL) of the applicable LS-500 series amplifier to level 2 or less. This is because there is a possibility of sensing becoming unstable.) Sensing range:H-SP mode 1m 3.281 ft (Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.) (Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.)
In StockNew Sealed Under Guarantee
Micro photoelectric sensor
PM-F65W-P
In StockNew Sealed Under Guarantee
PM2-LF10-C1
In StockNew Sealed Under Guarantee
PM-F65
In StockNew Sealed Under Guarantee
PM-F65-P
In StockNew Sealed Under Guarantee
PM-F65W
In StockNew Sealed Under Guarantee
PM2-LF10
In StockNew Sealed Under Guarantee
PM2-LH10
In StockNew Sealed Under Guarantee
PM2-LL10
In StockNew Sealed Under Guarantee
PM2-LL10B
In StockNew Sealed Under Guarantee
PM2-LL10-C1
In StockNew Sealed Under Guarantee
PM2-LF10B
In StockNew Sealed Under Guarantee
Photoelectric sensors
LX-111-P-Z
In StockNew Sealed Under Guarantee
EQ-34-J
In StockNew Sealed Under Guarantee
LX-111
In StockNew Sealed Under Guarantee
LX-111-P
In StockNew Sealed Under Guarantee
LX-111-Z
In StockNew Sealed Under Guarantee
EX-Z11FA-P-R
In StockNew Sealed Under Guarantee
EX-Z11A-P-R
In StockNew Sealed Under Guarantee
EX-Z12FA-P-R
In StockNew Sealed Under Guarantee
EX-Z12A-P-R
In StockNew Sealed Under Guarantee
EX-Z13FA-P-R
In StockNew Sealed Under Guarantee
EX-Z13A-P-R
In StockNew Sealed Under Guarantee
EX-Z11FB-P-R
In StockNew Sealed Under Guarantee
EX-Z11B-P-R
In StockNew Sealed Under Guarantee
EX-Z12FB-P-R
In StockNew Sealed Under Guarantee
EX-Z12B-P-R
In StockNew Sealed Under Guarantee
EX-Z13FB-P-R
In StockNew Sealed Under Guarantee
EX-Z13B-P-R
In StockNew Sealed Under Guarantee
CX-421-P
In StockNew Sealed Under Guarantee
CX-422-P
In StockNew Sealed Under Guarantee
CX-424-P
In StockNew Sealed Under Guarantee
0.949417s